Comparación de la penetración de distintas agujas de irrigación en endodoncia
Título
Comparación de la penetración de distintas agujas de irrigación en endodoncia
Penetration depth comparison between different endodontic irrigation needles
Autor
Fernandez Caiña, I.
Miqueo, S.
Gimenez, M.
Corominola, P. L.
Nastri, M. L.
Gualtieri, A. F.
Rodríguez, P. A.
Descripción
Resumen: Objetivo: Comparar la profundidad de penetración de las diferentes agujas de irrigación en endodoncia en conductos simulados previamente instrumentados con el sistema Protaper Gold (PTG) y WaveOne Gold (WOG). Materiales y métodos: En tacos de entrenamiento (Endo Training Bloc J-Shape Ø15.02 Taper, Dentsply Sirona) instrumentados con sistemas WOG y PTG (Dentsply Maillefer, Suiza) se midió la profundidad de penetración de 4 agujas de irrigación distintas. Los datos se analizaron mediante la prueba ANOVA de una vía, seguida por comparaciones post hoc empleando la prueba de Tukey-Kramer (p < 0,05, significativo). Resultados: Dentro del sistema PTG, la profundidad de penetración (mm) alcanzada por las agujas TruNatomy 30G (TNY), Neojet 25G (NEO), Max-I-Probe 30G (MIP) y 2 side vents 30G (2SV) tuvo una media (DE) de 14 (2), 11 (2), 11 (1) y 12 (1), respectivamente; con diferencias significativas entre TNY y NEO (p < 0,05), y entre TNY y MIP (p < 0,05). Con el sistema WOG se obtuvieron resultados similares: la profundidad media (DE) con agujas TNY, NEO, MIP y 2SV fue de 14 (1), 11 (1), 12 (1) y 13 (1), respectivamente; con diferencias significativas entre TNY y NEO (p < 0,05), y entre TNY y MIP (p < 0,05). Conclusiones: Los resultados sugieren que para ambos sistemas la aguja TNY alcanza mayor penetración que las agujas NEO y MIP. Posteriores trabajos podrían enfocarse a comparar, específicamente, la profundidad de penetración de los distintos instrumentos de cada sistema en función del material de confección de las agujas.
Abstract: Objective: To compare penetration depth of different endodontic irrigation needles in simulated canals previously treated with Protaper Gold (PTG) and WaveOne Gold (WOG) systems. Materials and methods: The penetration depth of 4 different irrigation needles was measured in training blocks (Endo Training Bloc J-Shape Ø15.02 Taper, Dentsply Sirona) instrumented with WOG and PTG systems (Dentsply Maillefer, Suiza). Data were analyzed by one-way ANOVA followed by post hoc comparisons using the Tukey-Kramer test (p < 0.05, significant). Results: Within the PTG system, the penetration depth (mm) achieved by the TruNatomy 30G (TNY), Neojet 25G (NEO), Max-I-Probe 30G (MIP) and 2 side vents 30G (2SV) needles had an mean depth (SD) of 14 (2), 11 (2), 11 (1) and 12 (1), respectively; with significant differences between TNY and NEO (p < 0.05), and between TNY and MIP (p < 0.05). Similar results were obtained with the WOG system: mean depth (SD) with TNY, NEO, MIP and 2SV needles was 14 (1), 11 (1), 12 (1) and 13 (1), respectively; also with significant differences between TNY and NEO (p < 0.05), and between TNY and MIP (p < 0.05). Conclusions: The results suggest that for both sistems the TNY needle achieves greater penetration than the NEO and MIP needles. Further works could focus on comparing, specifically, the penetration depth between the different instruments of each system and the needle manufacturing material.
Fil: Fernandez Caiña, I. Universidad de Buenos Aires. Facultad de Odontología. Cátedra de Endodoncia. Buenos Aires, Argentina.
Fil: Miqueo, S. Universidad de Buenos Aires. Facultad de Odontología. Cátedra de Endodoncia. Buenos Aires, Argentina.
Fil: Gimenez, M. Universidad de Buenos Aires. Facultad de Odontología. Cátedra de Endodoncia. Buenos Aires, Argentina.
Fil: Corominola, P. L. Universidad de Buenos Aires. Facultad de Odontología. Cátedra de Endodoncia. Buenos Aires, Argentina.
Fil: Nastri, M. L. Universidad de Buenos Aires. Facultad de Odontología. Cátedra de Endodoncia. Buenos Aires, Argentina.
Fil: Gualtieri, A. F. Universidad de Buenos Aires. Facultad de Odontología. Cátedra de Odontología Legal, Forense e Historia de la Odontología. Buenos Aires, Argentina.
Fil: Rodríguez, P. A. Universidad de Buenos Aires. Facultad de Odontología. Cátedra de Endodoncia. Buenos Aires, Argentina.
Fuente
Rev Fac Odontol, Univ Buenos Aires. 2025; 40(94), 21–26.
ISSN 1668-8538
Editor
Universidad de Buenos Aires. Facultad de Odontología.
Fecha
2025
Identificador
Extensión
6 pp.
Citación
Fernandez Caiña, I. et al., “Comparación de la penetración de distintas agujas de irrigación en endodoncia,” FOUBA Digital, consulta 12 de septiembre de 2026, https://repositorio.odontologia.uba.ar/items/show/1746.